Ambient Monitoring

During the application of a coating, the presence of moisture in the environment or on the work surface, often results in a poor quality finish. Problems such as poor adhesion of the coating or premature corrosion of the substrate can occur.

To determine the likelihood of moisture affecting the quality of the finish, it is essential that the surface temperature, air temperature, relative humidity (RH) and dew point are all measured.

NZ Inspection Rentals Ltd offer a range of ambient monitoring tools from simple whirling hygrometers recording wet and dry bulbs to data loggers with take ambient conditions throughout a particular project such as tank painting, internal factory floor coatings temporary abrasive blasting and painting booths.


 

Escort Data logger

Escort Data logger


 
Hygro-therometer Temperature and Humidity

Hygro-therometer Temperature and Humidity

This device is used to measure temperature, humidity, dew point and wet bulb temperature. With high accuracy capacitance humidity sensor, the device performs stably and precisely; it is dustproof and anti-static, often used in a blast & paint shop, warehouse, and greenhouse for temperature and humidity measurement.


 
Positector DPM (Dew Point Meter)

Positector DPM (Dew Point Meter)

Positector Dew Point Meter (DPM) This is the complete data logger with air, surface, relative humidity and dew point logging capabilities.These are PC compatable and the graphs Microsoft Excel compatable.

Measures and records climatic parameters including: Relative humidity, air temperature, surface temperature, dew point temperature and difference between surface and dew point temperatures. Ideal for surface preparation as required by ISO 8502-4 , BS 7079-B4, ASTM D3276-05 , NSTM 009-32 , IMO PSPC , and SSPC-PA7.

See a You Tube demo by following this link: https://www.youtube.com/watch?v=H-tZBR9KVuI

 


 
Whirling Hygrometer

Whirling Hygrometer

Simple to use, just open the wick container wet the wick thoroughly, ensuring that the wick on the thermometer bulb is wet. Then holding the thermometer case horizontally, rotate the instrument for 15 to 20 seconds.

Record temperatures of the wet bulb first and then the dry bulb and calculate the wet bulb depression- this is the difference between the two readings.

Then using the enclosed chart look where the wet bulb depression is to determine the % relative humidity.

No battery required.


 

Prices are displayed in NZ dollars & incl GST.

NZ Corrosion Services Limited  - New Zealand. Protective Coatings and Corrosion. Consulting, Paint Inspection, Th

For over 10 years we are pleased to offer our on-going support for training and development in the protective coatings and linings industries throughout New Zealand & Australia.
NZCS supports the following organisations in this roll.

NZ Corrosion Services Limited  - New Zealand. Protective Coatings and Corrosion. Consulting, Paint Inspection, ThNZ Corrosion Services Limited  - New Zealand. Protective Coatings and Corrosion. Consulting, Paint Inspection, ThNZ Corrosion Services Limited  - New Zealand. Protective Coatings and Corrosion. Consulting, Paint Inspection, ThNZ Corrosion Services Limited  - New Zealand. Protective Coatings and Corrosion. Consulting, Paint Inspection, ThNZ Corrosion Services Limited  - New Zealand. Protective Coatings and Corrosion. Consulting, Paint Inspection, Th